Company
Methodology
How we measure uptime, throughput and latency, how the 99.99% SLA is calculated and credited, and which figures we will not publish, and why.
Every number on this site is produced by a method that is written down before the number is published. This page is the method. If a figure cannot be reproduced from what is described here, it will be withdrawn.
The short version: uptime comes from external probes, throughput from a fixed iperf3 procedure, latency from three fixed vantage points, and the SLA from the same probe data the status page uses.
How uptime is sampled
Five external probes in Reykjavík, Zürich, Amsterdam, Bucharest and Panama City each check every instance's TCP port and an HTTP health endpoint once every sixty seconds. A minute is up if all five probes fail to get a response, which removes single-probe false positives from a local transit flap.
Uptime for a month is the number of up minutes divided by the number of minutes in that month. Planned maintenance announced at least seventy-two hours ahead is excluded, and there is no other exclusion. Unannounced maintenance counts against us.
Raw probe data for the trailing ninety days is available on request from the ticket desk, per instance, as CSV.
How the SLA is calculated
The SLA is 99.99% on VPS and dedicated plans, measured on the same probe set. Over a thirty-day month that is four minutes and nineteen seconds of permitted downtime. Over a thirty-one day month it is four minutes and twenty-eight seconds.
A credit claim requires a ticket within seven days of the incident, and the credit is calculated from the published table rather than negotiated: 99.99% to 99.95% gives ten per cent of the monthly fee, 99.95% to 99.0% gives twenty-five, below 99.0% gives fifty, and below 95.0% gives a full month.
Credits are applied to the next invoice. We do not pay cash for downtime, and we do not count a credit as a refund for the purposes of the seven-day money-back window.
How throughput is published
Throughput figures come from iperf3 between the instance and a probe host in the same facility, three runs of thirty seconds, reporting the median. Single-stream and eight-stream results are both recorded, and the plan table quotes the figure a customer is most likely to see on a single connection.
We run the test on a freshly provisioned instance with no other tenants active on the host, and then again on a loaded host, and publish the lower number. The first number is the marketing one and the second is the useful one.
Bandwidth allowances are counted at the virtual NIC. Traffic dropped by the scrubber does not count, which matters after an attack and is stated on every invoice.
How latency is reported
Latency figures are round-trip medians over ten thousand ICMP packets from three fixed vantage points per location, taken within the same hour, on a weekday. They are stated as a range rather than a single number because a single number is always the best minute of the day.
The vantage points are consumer connections on fiber, not datacenter drops, because a datacenter-to-datacenter ping is a number that no customer will ever reproduce.
Where a figure depends on the user's network, we say so. Reykjavík to London is about thirty-five milliseconds and it will be thirty-eight on a bad afternoon.
What we do not publish
No benchmark scores. A synthetic CPU score on a shared host says more about the neighbor than about the plan, and every vendor quotes the good run.
No aggregate attack volume as a headline. We publish scrubbing capacity per plan because that is a contract term; we do not publish the largest attack absorbed as a marketing number, because it invites a larger one and cannot be verified by anyone outside the facility.
No customer counts, revenue or growth figures.
Corrections
When a published figure turns out to be wrong, the page is corrected and a dated note is appended saying what changed and why. The note stays for twelve months.
If the error came from a method rather than a transcription, the method section is amended in the same edit. Quietly editing a number without the note is the one thing that would make this page worthless.
FAQ
Questions we get on this page
Why 99.99% and not 100%?+
Do the probes run from inside your network?+
Ready when you are
Tell us what you need. A human answers.
Pilot stage: one facility in Reykjavík, plans confirmed by hand, payment in crypto. Write to the desk and you get a real person, not a queue.